Fixed Nozzle Desuperheater (FND) Features Single nozzle Kv as low as 0.0162 m3/hr and as high as 1.6 m3/hr Number of nozzles limited only by pipeline diameter For use on all pipe sizes 6" and above Ideal for use in conjunction with water control valve and control system Turndown ratio up to 4 : 1 (Depending on water quantity)
Notes Minimum pipe size required for installation of FND is 150mm Water pressure should be minimum 7 bar more than the steam pressure maximum recommended pressure difference between steam and water is 45 bar. if it exceeds 45 bar then install pressure control valve in waterline to reduce water pressure within limits Spray water should be very clean (equivalent to boiler feedwater) IBR approval shall be provided for individual components Turndown ratio up to 1 : 4
Typical Sizes Steam side flange : 4" and water side flange 1" / 1 1/2" OR Steam side flange : 6" and water side flange 2" Pressure rating :upto ANSI #2500
Advantages Custom made for any size, standard or range Simple installation Can be used for higher pipe size and low steam pressure No moving parts