Transaksi yang dilakukan di Indotrading dijamin aman karena uang yang Anda bayarkan akan diteruskan kepenjual setelah Indotrading mendapat konfirmasi penerimaaan barang dari kedua pihak. Silahkan melakukan transaksi dengan cara buat permintaan beli, terima penawaran, beli dari penawaran yang Anda terima dan bayarkan biaya ke Indotrading.com Selengkapnya

Spesifikasi AC Current Detection Relay

AC under Current Relay DUC-2 (0-2Amp)

The DUC-2 monitors alternating current. Its setting is adjustable from zero to 2.0A. The current circuit is
connected to terminals S1 and S2 either directly or through current transformers.
The DUC-2 is designed to sense under current. When the measured current is above the setting, an
internal relay will energize and the green Up LED comes ON while the red Trip LED is OFF. If the
current drops below the setting, the relay releases and the green Up LED goes OFF while the red Trip
LED comes ON. Contacts 11-14 close in the Up condition and open in the Trip or No Supply condition.
Technical Data
Supply Voltage : ❑240VAC ❑115VAC
❑24VDC ❑12VDC
Frequency : 50~60Hz
Consumption : 2VA Voltage Circuit
: 1VA Current Circuit
ON/TRIP Hysteresis : 2% of rated
Current Adjustment : 0 - 2A
Indication : Green LED (Up)
Red LED (Trip)
Dielectric Strength Between:Current & Voltage Circuit : 3 kV
Output & Voltage Circuit : 2 kV
Output Contacts : 2 kV
Output Contacts : 5A 240V 50Hz AC1
Relay Up 11-14 Close;11-12 Open;
Relay Trip 11-14 Open;11-12 Close

 

AC under Current Relay DUC-2D

AC Under Current Relay (0-2A) with Delay
Utilization:
The DUC-2D monitors alternating current. Its current setting is adjustable from zero to 2.0A and the
delay setting is adjustable from 0 to 20 sec. The current circuit is connected to terminals S1 and S2 either
directly or through current transformers.
The DUC-2D is designed to sense under current. When the measured current is above the setting, an
internal relay will energize and the green Up LED comes ON while the Amber Delay LED and the red
Trip LED are OFF. If the current drops below the setting, the Amber Delay LED comes ON; then after
the set delay, the relay releases and the green Up LED goes OFF while the red Trip LED comes ON.
Technical Data
Supply Voltage : ❑240VAC ❑115VAC
❑24VDC ❑12VDC
Frequency : 50~60Hz
Consumption : 2VA Voltage Circuit
: 1VA Current Circuit
ON/TRIP Hysteresis : 2% of rated
Current Adjustment : 0 - 2A
Delay Adjustment : 0 - 20 Sec
Indication : Green LED (Up)
Amber LED (Delay)
Red LED (Trip)
Dielectric Strength Between:Current & Voltage Circuit : 3 kV
Output & Voltage Circuit : 2 kV
Output Contacts : 2 kV
Output Contacts : 5A 240V 50Hz AC1
Relay Up 11-14 Close;11-12 Open
Relay Trip 11-14 Open;11-12 Close

AC Under Current Relay (0-2A) with 2 Contacts DUC2-2
Utilization:
The DUC2-2 monitors alternating current. Its setting is adjustable from zero to 2.0A. The current circuit
is connected to terminals S1 and S2 either directly or through current transformers.
The DUC2-2 is designed to sense under current. When the measured current is above the setting, two
internal relays will energize and the green Up LED comes ON while the red Trip LED is OFF. If the
current drops below the setting, the relays release and the green Up LED goes OFF while the red Trip
LED comes ON. Contacts 11-14 & 21-24 close in the Up condition and open in the Trip or No Supply
condition.
Technical Data
Supply Voltage : ❑240VAC ❑115VAC
Frequency : 50~60Hz
Consumption : 2VA Voltage Circuit
: 1VA Current Circuit
ON/TRIP Hysteresis : 2% of rated
Current Adjustment : 0 - 2A
Indication : Green LED (Up)
Red LED (Trip)
Dielectric Strength Between:
Current & Voltage Circuit : 3 kV
Output & Voltage Circuit : 2 kV
Output Contacts : 2 kV
Output Contacts : 5A 240V 50Hz AC1
Relay Up
11-14 Close
11-12 Open
21-24 Close
21-22 Open
Relay Trip
11-14 Open
11-12 Close
21-24 Open
21-22 Close

AC Under Current Relay (0-2A) with 2 Contacts and Delay Type DUC2-2D

Utilization:
The DUC2-2D monitors alternating current. Its current setting is adjustable from zero to 2.0A and the
delay setting is adjustable from 0 to 20 sec. The current circuit is connected to terminals S1 and S2 either
directly or through current transformers.
The DUC2-2D is designed to sense under current. When the measured current is above the setting, two
internal relays will energize and the green Up LED comes ON while the Amber Delay LED and the red
Trip LED are OFF. If the current drops below the setting, the Amber Delay LED comes ON; then after
the set delay, the relays release and the green Up LED goes OFF while the red Trip LED comes ON.
Contacts 11-14 & 21-24 close in the Up condition and open in the Trip or No Supply condition.
Technical Data
Supply Voltage : ❑240VAC ❑115VAC
❑24VDC ❑12VDC
Frequency : 50~60Hz
Consumption : 2VA Voltage Circuit
: 1VA Current Circuit
ON/TRIP Hysteresis : 2% of rated
Current Adjustment : 0 - 2A
Delay Adjustment : 0 - 20 Sec
Indication : Green LED (Up)
Amber LED (Delay)
Red LED (Trip)
Dielectric Strength Between:
Current & Voltage Circuit : 3 kV
Output & Voltage Circuit : 2 kV
Output Contacts : 2 kV
Output Contacts : 5A 240V 50Hz AC1
Relay Up
11-14 Close
11-12 Open
21-24 Close
21-22 Open
Relay Trip
11-14 Open
11-12 Close
21-24 Open
21-22 Close

AC Under Current Relay (0-5A) Model DUC-5
Utilization:
The DUC-5 monitors alternating current. Its setting is adjustable from zero to 5.0A. The current circuit
is connected to terminals S1 and S2 either directly or through current transformers.
The DUC-5 is designed to sense under current. When the circuit current is above the setting, an internal
relay will energize and the red Trip LED goes OFF while the green Up LED comes ON. If the current
drops below the setting, the relay releases and the red Trip LED comes ON while the green Up LED goes
OFF. Contacts 11-14 close in the Up condition and open in the Trip or No Supply condition.
Technical Data
Supply Voltage : ❑240VAC ❑115VAC
❑24VDC ❑12VDC
Frequency : 50~60Hz
Consumption : 2VA Voltage Circuit
: 1VA Current Circuit
ON/TRIP Hysteresis : 3% of rated
Current Adjustment : 0 - 5A
Indication : Green LED (Up)
Red LED (Trip)
Dielectric Strength Between:
Current & Voltage Circuit : 3 kV
Output & Voltage Circuit : 2 kV
Output Contacts : 2 kV
Output Contacts : 5A 240V 50Hz AC1
Relay Up
11-14 Close
11-12 Open
Relay Trip
11-14 Open
11-12 Close

AC Under Current Relay (0-5A) with Delay model DUC-5D
Utilization:
The DUC-5D monitors alternating current. Its current setting is adjustable from zero to 5A and the delay
setting is adjustable from 0 to 20 sec. The current circuit is connected to terminals S1 and S2 either
directly or through current transformers.
The DUC-5D is designed to sense under current. When the measured current is above the setting, an
internal relay will energize and the green Up LED comes ON while the Amber Delay LED and the red
Trip LED are OFF. If the current drops below the setting, the Amber Delay LED comes ON; then after
the set delay, the relay releases and the green Up LED goes OFF while the red Trip LED comes ON.
Technical Data
Supply Voltage : ❑240VAC ❑115VAC
❑24VDC ❑12VDC
Frequency : 50~60Hz
Consumption : 2VA Voltage Circuit
: 1VA Current Circuit
ON/TRIP Hysteresis : 2% of rated
Current Adjustment : 0 - 5A
Delay Adjustment : 0 - 20 Sec
Indication : Green LED (Up)
Amber LED (Delay)
Red LED (Trip)
Dielectric Strength Between:
Current & Voltage Circuit : 3 kV
Output & Voltage Circuit : 2 kV
Output Contacts : 2 kV
Output Contacts : 5A 240V 50Hz AC1
Relay Up
11-14 Close
11-12 Open
Relay Trip
11-14 Open
11-12 Close

AC Under Current Relay (0-10A) Model DUC-10
Utilization:
The DUC-10 monitors alternating current. Its setting is adjustable from zero to 10A. The current circuit
is connected to terminals S1 and S2 either directly or through current transformers.
The DUC-10 is designed to sense under current. When the circuit current is above the setting, an internal
relay will energize and the red Trip LED goes OFF while the green Up LED comes ON. If the current
drops below the setting, the relay releases and the red Trip LED comes ON while the green Up LED goes
OFF. Contacts 11-14 close in the Up condition and open in the Trip or No Supply condition.
Technical Data
Supply Voltage : ❑240VAC ❑115VAC
❑24VDC ❑12VDC
Frequency : 50~60Hz
Consumption : 2VA Voltage Circuit
: 1VA Current Circuit
ON/TRIP Hysteresis : 2% of rated
Current Adjustment : 0 - 10A
Indication : Green LED (Up)
Red LED (Trip)
Dielectric Strength Between:
Current & Voltage Circuit : 3 kV
Output & Voltage Circuit : 2 kV
Output Contacts : 2 kV
Output Contacts : 5A 240V 50Hz AC1
Relay Up 11-14 Close;11-12 Open
Relay Trip 11-14 Open;11-12 Close

AC Under Current Relay (0-5A) with 2 Contacts Model DUC2-5
Utilization:
The DUC2-5 monitors alternating current. Its setting is adjustable from zero to 5.0A. The current circuit
is connected to terminals S1 and S2 either directly or through current transformers.
The DUC2-5 is designed to sense under current. When the circuit current is above the setting, two
internal relays will energize and the red Trip LED goes OFF while the green Up LED comes ON. If the
current drops below the setting, the relays release and the red Trip LED comes ON while the green Up
LED goes OFF. Contacts 11-14 & 21-24 close in the Up condition and open in the Trip or No Supply
condition.
Technical Data
Supply Voltage : ❑240VAC ❑115VAC
❑24VDC ❑12VDC
Frequency : 50~60Hz
Consumption : 2VA Voltage Circuit
: 1VA Current Circuit
ON/TRIP Hysteresis : 2% of rated
Current Adjustment : 0 - 5A
Indication : Green LED (Up)
Red LED (Trip)
Dielectric Strength Between:
Current & Voltage Circuit : 3 kV
Output & Voltage Circuit : 2 kV
Output Contacts : 2 kV
Output Contacts : 5A 240V 50Hz AC1
Relay Up
11-14 Close
11-12 Open
21-24 Close
21-22 Open
Relay Trip
11-14 Open
11-12 Close
21-24 Open
21-22 Close

AC Under Current Relay (0-5A) with 2 Contacts and Delay Model DUC2-5D
Utilization:
The DUC2-5D monitors alternating current. Its current setting is adjustable from zero to 5A and the delay
setting is adjustable from 0 to 20 sec. The current circuit is connected to terminals S1 and S2 either
directly or through current transformers.
The DUC2-5D is designed to sense under current. When the measured current is above the setting, two
internal relays will energize and the green Up LED comes ON while the Amber Delay LED and the red
Trip LED are OFF. If the current drops below the setting, the Amber Delay LED comes ON; then after
the set delay, the relays release and the green Up LED goes OFF while the red Trip LED comes ON.
Contacts 11-14 & 21-24 close in the Up condition and open in the Trip or No Supply condition.
Technical Data
Supply Voltage : ❑240VAC ❑115VAC
❑24VDC ❑12VDC
Frequency : 50~60Hz
Consumption : 2VA Voltage Circuit
: 1VA Current Circuit
ON/TRIP Hysteresis : 2% of rated
Current Adjustment : 0 - 5A
Delay Adjustment : 0 - 20 Sec
Indication : Green LED (Up)
Amber LED (Delay)
Red LED (Trip)
Dielectric Strength Between:
Current & Voltage Circuit : 3 kV
Output & Voltage Circuit : 2 kV
Output Contacts : 2 kV
Output Contacts : 5A 240V 50Hz AC1
Relay Up
11-14 Close
11-12 Open
21-24 Close
21-22 Open
Relay Trip
11-14 Open
11-12 Close
21-24 Open
21-22 Close

AC Under Current Relay (0-8A) with 2 Contacts and Delay Model DUC2-8D
Utilization:
The DUC2-8D monitors alternating current. Its current setting is adjustable from zero to 8A and the delay
setting is adjustable from 0 to 20 sec. The current circuit is connected to terminals S1 and S2 either
directly or through current transformers.
The DUC2-8D is designed to sense under current. When the measured current is above the setting, two
internal relays will energize and the green Up LED comes ON while the Amber Delay LED and the red
Trip LED are OFF. If the current drops below the setting, the Amber Delay LED comes ON; then after
the set delay, the relays release and the green Up LED goes OFF while the red Trip LED comes ON.
Contacts 11-14 & 21-24 close in the Up condition and open in the Trip or No Supply condition.
HOKKIM
giving you control Control & Protection Relays
DUC2-8D
AC Under Current
Relay
12 14 11 21 24 22
8
2 6
4
4
8 12
16
20
Delay
Technical Data
Supply Voltage : ❑240VAC ❑115VAC
❑24VDC ❑12VDC
Frequency : 50~60Hz
Consumption : 2VA Voltage Circuit
: 1VA Current Circuit
ON/TRIP Hysteresis : 2% of rated
Current Adjustment : 0 - 8A
Delay Adjustment : 0 - 20 Sec
Indication : Green LED (Up)
Amber LED (Delay)
Red LED (Trip)
Dielectric Strength Between:
Current & Voltage Circuit : 3 kV
Output & Voltage Circuit : 2 kV
Output Contacts : 2 kV
Output Contacts : 5A 240V 50Hz AC1
Relay Up 11-14 Close
11-12 Open
21-24 Close
21-22 Open
Relay Trip 11-14 Open
11-12 Close
21-24 Open
21-22 Close

AC Over Current Relay (0-2A) Model DOC-2
Utilization:
The DOC-2 monitors alternating current. Its setting is adjustable from zero to 2.0A. The current circuit
is connected to terminals S1 and S2 either directly or through current transformers.
The DOC-2 is designed to sense over current. When the measured current is below the setting, an internal
relay will energize and the green Up LED comes ON while the red Trip LED is OFF. If the current rises
above the setting, the relay releases and the green Up LED goes OFF while the red Trip LED comes ON.
Contacts 11-14 close in the Up condition and open in the Trip or No Supply condition.
Technical Data
Supply Voltage : ❑240VAC ❑115VAC
❑24VDC ❑12VDC
Frequency : 50~60Hz
Consumption : 2VA Voltage Circuit
: 1VA Current Circuit
ON/TRIP Hysteresis : 2% of rated
Adjustment : 0 - 2A
Indication : Green LED (Up)
Red LED (Trip)
Dielectric Strength Between:
Current & Voltage Circuit : 3 kV
Output & Voltage Circuit : 2 kV
Output Contacts : 2 kV
Output Contacts : 5A 240V 50Hz AC1
Relay Up 11-14 Close; 11-12 Open
Relay Trip 11-14 Open; 11-12 Close

AC Over Current Relay (0-2A) with Delay Model DOC2-2D
Utilization:
The DOC-2D monitors alternating current. Its current setting is adjustable from zero to 2.0A and the
delay setting is adjustable from 0 to 20 sec. The current circuit is connected to terminals S1 and S2 either
directly or through current transformers.
The DOC-2D is designed to sense over current. When the measured current is below the setting, an
internal relay will energize and the green Up LED comes ON while the Amber Delay LED and the red
Trip LED are OFF. If the current rises above the setting, the Amber Delay LED comes ON; then after the
set delay, the relay releases and the green Up LED goes OFF while the red Trip LED comes ON.
Technical Data
Supply Voltage : ❑240VAC ❑115VAC
❑24VDC ❑12VDC
Frequency : 50~60Hz
Consumption : 2VA Voltage Circuit
: 1VA Current Circuit
ON/TRIP Hysteresis : 2% of rated
Current Adjustment : 0 - 2A
Delay Adjustment : 0 - 20 Sec
Indication : Green LED (Up)
Amber LED (Delay)
Red LED (Trip)
Dielectric Strength Between:
Current & Voltage Circuit : 3 kV
Output & Voltage Circuit : 2 kV
Output Contacts : 2 kV
Output Contacts : 5A 240V 50Hz AC1
Relay Up 11-14 Close;11-12 Open
Relay Trip 11-14 Open;11-12 Close

Harga AC Current Detection Relay

: CALL
Kami Merupakan perusahaan yang bergerak di bidang penjualan Modul-modul seperti SSR, Thyristor, IGBT, Noise Filter, Dioda, Power Supply, HMI,Inverter, PLC, Photo Electric Sensor, Proximity Switch dan product Instrument Control lainnnya.
produk-produk ini kami stockist dan kami import dari China, Hongkong, Italy, Singapura.
kami yakin bisa memberikan harga terbaik kepada para langganan kami

Kami Menjual
  • Solid State Relay
  • Noise Filter
  • Thyristor
  • Dioda
  • Igbt
  • Power Supply

Simulasi Pinjaman Usaha

Rp (Juta)
%
Hari
Hari
Hari
Rp (Juta)
uob
Mau bunga kredit 8.99%?
IndoTrading.com adalah media iklan khusus Perusahaan, Toko, Distributor, Grosir, Agen, Supplier, Importir, Exportir, Trading dan Pabrik. Jika Anda tertarik untuk membeli AC Current Detection Relay ini dengan harga murah, Mohon hubungi Kontak Perusahaan ini diatas.

Jika Anda adalah perusahaan yang ingin menjual di IndoTrading.com ,
--%>