Transaksi yang dilakukan di Indotrading dijamin aman karena uang yang Anda bayarkan akan diteruskan kepenjual setelah Indotrading mendapat konfirmasi penerimaaan barang dari kedua pihak. Silahkan melakukan transaksi dengan cara buat permintaan beli, terima penawaran, beli dari penawaran yang Anda terima dan bayarkan biaya ke Indotrading.com Selengkapnya

Spesifikasi Ammonia Meter HI96700 Photometer Hanna Instruments

Ammonia Meter HI96700 Photometer Hanna Instruments

The HI96700 Ammonia Low Range Photometer combines accuracy and ease of use in an ergonomic, portable design. A user can accurately determine the concentration of ammonia ( as NH3-N ) in freshwater samples within a 0.00 to 3.00 mg/L ( ppm ) range using the HI93700-0 ready made reagents. The HI96700 offers many advanced features including the exclusive CAL Check™ function used for performance verification and calibration of the meter.
Ready-made reagents ordered separately
CAL Check™ validation and calibration option
Built-in timer for appropriate reaction interval
Details
The HI96700 portable photometer is for the measurement of ammonia nitrogen ( NH3-N ) in freshwater samples. Hanna's portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check™ feature utilizes ready-made standards traceable to a NIST Standard for performance verification and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.&nbsp
Features at-a-glance
CAL Check™ - Allows for performance verification and calibration of the meter using a CAL Check NIST traceable secondary standard.
GLP - Records the date of the last user calibration performed.
Built in timer - Ensures the appropriate reaction time is used for the chemical reaction. At the end of the timer the meter will automatically take the reading. This feature ensures consistency across multiple users.
Indexing indent on meter - The meter has an indent that allows for a lock and key fit with the cuvette cap. This ensures that the cuvette is indexed consistently ( same position ) in order to maintain the same path length for accurate results.
Cooling Lamp Indicator - It is necessary to maintain a consistent temperature of the optical components in order to maintain a narrow wavelength band of light. This photometer has a cooling lamp indicator that is displayed for a short period of time before each measurement in order to allow the components to cool and obtain the highest accuracy possible.
Error messages - Messages on display alerting to problems including no cap, over range and under range readings, and light source error.
Auto-shut off - Automatic shut off after 10 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally not turned off.
Battery status indicator
The instrument has a battery level indicator to display reaming life as follows :
3 lines for 100 % capacity
2 lines for 66 % capacity
1 line for 33 % capacity
Battery icon blinks when the capacity is less than 10 %.
Units of measure - Appropriate unit of measure is displayed along with reading.

photometer optical system

Present naturally in surface and wastewaters, ammonia mainly results from the deamination of organic nitrogen-containing compounds and hydrolysis of urea. Ammonia may also be present from water treatment processes that utilize chloramaines for disinfection, where ammonia is added to the water to react with chlorine. Ammonia is less likely to appear in groundwater due to adsorption to soil particles.

The HI96700 uses an adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92 Nessler method to measure ammonia concentrations of less than 3.00 mg/L ( ppm ) ammonia-nitrogen. When the Nessler reagent is added to samples containing ammonia, the sample will turn a yellow hue; the greater the concentration, the deeper the color. The associated color change is then colorimetrically analyzed according to the Beer-Lambert Law. This principle states that light is absorbed by a complimentary color, and the emitted radiation is dependent upon concentration. For low levels of ammonia, a narrow band interference filter at 420 nm ( violet ) allows only violet light to be detected by the silicon photodetector and omits all other visible light emitted from the tungsten lamp. As the change in color of the reacted sample increases, absorbance of the specific wavelength of light also increases, while transmittance decreases.

The HI96700 is available as a kit ( HI96700C ) which includes :

  • Portable Photometer
  • Sample cuvettes ( 2 )
  • Caps
  • CAL Check™ standards with certificate
  • Cuvette cleaning cloth
  • Rugged carrying case
    • Carrying case has thermoformed insert for meter and accessories

*Reagents ordered separately

cal check standards

CAL Check™ standards with certificate

The HI96700-11 CAL Check™standards are used for calibration and performance verification of photometers with the CAL Check function.

Supplied with Certificate of Analysis

  • Lot number
  • Expiration date
  • Standard value @ 25 °C
  • Reference meter NIST traceable

Provided storage containers

  • Light tight
  • Protects from accidental breakage

 

Absorbance Specifications

Light Source tungsten lamp
Light Detector silicon photocell with narrow band interference filter @ 420 nm

Additional Specifications

Range 0.00 to 3.00 mg/L ( ppm ) ( as ammonia-nitrogen )
Resolution 0.01 mg/L
Accuracy @ 25°C ( 77°F ) ±0.04 mg/L ±4% of reading
Method adaptation of the ASTM Manual of Water and Environmental Technology, D1426-93, Nessler method
Auto-off after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder
Environment 0 to 50°C ( 32 to 122°F ); RH max 95% non-condensing
Weight 360 g ( 12.7oz. )
Battery Type 9 V battery
Dimensions 193 x 104 x 69 mm ( 7.6 x 4.1 x 2.7” )
Ordering Information HI96700 is supplied with sample cuvettes ( 2 ) with caps, 9 V battery, instrument quality certificate and instruction manual.
Warranty 2 years

Alat Uji Kualitas Air 

Harga Ammonia Meter HI96700 Photometer Hanna Instruments

: CALL
Pallscientific, Adalah Perusahaan Swasta Nasional Yang Bergerak Di Bidang Hygiene Industri Dan Kesehatan Lingkungan. Bertujuan Untuk Menjembatani Dan Memenuhi Kebutuhan Dunia Industri Khususnya Dan Masyarakat Pada Umumnya. Perusahaan Yang Bergerak Di Bidang Perdagangan Barang Dan Jasa Dengan Meng-Khususkan Lingkup Usaha Perusahaan Dalam Bidang Pengadaan Peralatan Hygiene Industri Dan Kesehatan Lingkungan, Peralatan Laboratorium, Alat &Ndash; Alat Kesehatan, Serta Penyediaan Jasa Pemantauan, Pengukuran Lingkungan Dan Perbaikan Peralatan.Perdagangan Barang.Produk Yang Diperdagangkan Perusahan Utamanya Adalah Produk Produk Yang Berkaitan Dengan Hygiene Industri, Kesehatan Lingkungan, Kesehatan & Keselamatan Kerja Dan Peralatan Laboratorium Dan Alat Alat Kesehatan . Produk Produk Tersebut Antara Lain :A. Peralatan Pemantau Hygiene Industri Dan Keselamatan Kerja Peralatan Pemantau Higiene Industri Dan Keselamatan Kerja Meliputi :- Alat Ukur Suara ( Sound Level Meter & Noise Dosimeter)- Alat Ukur Getaran ( Vibration Monitoring)- Alat Detector Gas Berbahaya & Mudah Terbakar ( Gas & Flamable GasDetector)- Alat Untuk Pengambilan Sampel Gas, Debu, Mist, Fume & Aerosol ( Gas, Fume,Aerosol Sample Pump & Monitoring)B. Peralatan Pemantau Lingkungan Jenis Peralatan Tersebut Antara Lain :- Peralatan Sampling Dan Analisa Udara Maupun Peralatan Untuk SamplingKualitas Udara Pada Cerobong Secara Isokinetik Otomatis- Alat Pantau Cuaca Stasioner Yang Dilengkapi Dengan Penyimpanan Data ( DataLogging) Sesuai Parameter Yang Diukur.- Peralatan Pemantau Kwalitas Air Bersih Dan Air Minum ( Microbiologi, Ph,Turbiditi Dll..)- Perlatan Pewantau Kadar Kimia Dalam MakananC. Scientific Instrument , Untuk :- Laboratorium Kimia Dasar & Kimia Klinik : Laboratorium Bio Kimia, KimiaKlinik , Kimia Analitik, Mikrobiologi, Hematologi, Parasitologi, KimiaFarmasi & Toksikologi, Serologi, Virologi & Immunologi, Kimia Air, KimiaMakanan & Minuman, Dll- Laboratorium Fisika & Biologi : Laboratorium Instrumentasi, Fisika Dasar,Elektronika Medik, Radiology, Alat Elektronik, Elektronika Medik, Anatomi& Fisiology, Farmakologi Dll.D. Media Dan Reagensia, Untuk: Menunjang Kebutuhan Reagent Pada Rumah Sakit ,Puskesmas, Klinik, Dan Laboratorium.

Kami Menjual
  • Environmental
  • Medical
  • Instruments
  • Agriculture
  • Laboratory
  • Safety Equipment

Dapatkan penawaran terbaik untuk
Ammonia Meter HI96700 Photometer Hanna Instruments !

Nama
Quantity
Unit
Buat Permintaan

Simulasi Pinjaman Usaha

Rp (Juta)
%
Hari
Hari
Hari
Rp (Juta)

PERUSAHAAN TERKAIT

Tohodo Scientific Instrument

Verified Icon Verified
Indotrading gold member
1 Tahun
Response Rate 72%

UD. Tirta Masindo

Verified Icon Verified
Indotrading gold member
3 Tahun
Response Rate 20%

CV. Jamatindo Putra

Verified Icon Verified
Indotrading gold member
2 Tahun
Response Rate 45%
IndoTrading.com adalah media iklan khusus Perusahaan, Toko, Distributor, Grosir, Agen, Supplier, Importir, Exportir, Trading dan Pabrik. Jika Anda tertarik untuk membeli Ammonia Meter HI96700 Photometer Hanna Instruments ini dengan harga murah, Mohon hubungi Kontak Perusahaan ini diatas.

Jika Anda adalah perusahaan yang ingin menjual di IndoTrading.com ,
Perusahaan
PSC

1 Tahun Perusahaan ini adalah Anggota Platinum Member Berbayar IndoTrading.com. Kami telah melakukan verifikasi Alamat dan Eksistensi Perusahaan ini.
Response Rate :
reply_all 96%
Lindeteves Trade Center LTC Lantai 1 Blok B 21 No.3 Jl. Hayam Wuruk 127 Glodok Jakarta Barat 11180 Jakarta Barat, DKI Jakarta - Indonesia
Arrow