Spesifikasi Amprobe CT-53 Flex Current Sensor for DM-5
Amprobe CT-53 Flex Current Sensor for DM-5
SKU: 4726219
Features | CT-53 FlexCurrent Sensor |
Currentranges | 300 A /1000 A / 3000 A, AC rms |
Outputvoltage | 300 Arange: 500 mVac / 300 Aac (1.67 mV / A) 1000 A range: 500 mVac / 1000 Aac (0.5 mV / A) 3000 A range: 500 mVac / 3000 Aac (0.167 mV / A) |
Measuringrange | 300 Arange: 30 A to 300 A (424 Apeak) 1000 A range: 100 A to 1000 A (1414 Apeak) 3000 A range: 300 A to 3000 A (4243 Apeak) |
Accuracy (sinewave) | ±1.0% (45Hz to 65 Hz) |
Phasecharacteristics | Within ±1° 300 A range: 30 A to 300 A (45 Hz to 65 Hz) 1000 A range: 100 A to 1000 A (45 Hz to 65 Hz) 3000 A range: 300 A to 3000 A (45 Hz to 65 Hz) |
Workingvoltage | 600 Vacrms |
Maxallowed input | 3600 Aaccontinuous (45 Hz to 65 Hz) |
Measurableconductor size | Max. 5.9in (15 cm) diameter |
Headcircumference | 21.65 in(55 cm) |
Head cablediameter | 0.56 in(14.3 mm) |
Cablelength (head to electronics) | Approx.6.56 ft (2 m) |
Cablelength (output cable) | Approx.3.28 ft (1 m) |
Outputterminal | Mini-DIN-6connector |
Outputimpedance | 100 Ω orless |
Currentconsumption (at power supply 3 V) | 15 mA(typical) |
Operatingtemperature and humidity | 32 °F to122 °F (0 °C to 50 °C), ≤85 %RH (no condensation) Guaranteed accuracy at 73 °F ± 9 °F (23 °C ± 5 °C), ≤85 %RH (no condensation) |
Storagetemperature and humidity | -4 to 140°F (-20 °C to 60 °C), ≤85 % RH (no condensation) |
Operatingaltitude | 0 to 6,561ft (0 to 2,000 m) |
EMC | EN 61326 |
Safetycompliance | UL/IEC61010-1, IEC 61010-2-030, IEC 61010-2-032 Measurement CAT III 600 V,Pollution degree 2 |
Certification | (UL testedwith DM-5) |
Weight | Approx.2.1 lb (950 g) |