XGT Series Ladder programming PLC XGR


Redundancy system for high-speed process control based on IEC

 

  • Processing speed: 42ns/step
  • I/O Points: Max. 131,072
  • Total memory: 25MB (Program 3MB, System 4MB, Data 2MB, Flash 16MB)
  • Switching over time: 50ms
  • Built-in 256 PID loops control



Features :


High performance

 

  • Processing speed: 42ns/step
  • CPU synchronization via fiber optic cable
  • I/O Points: Max. 131,072
  • Total memory: 25MB (Program 3MB, System 4MB, Data 2MB, Flash 16MB)
  • Switching over time: 22ms

 

Easy expansion installation using network

 

  • Max.31 expansion base
  • Distance: Fiber optic 2km (Max. expansion 60km), Twisted fair 100m (Max. expansion 3km)
  • Program upload and download via expansion base
  • No limit to install the communication master on the expansion base

 

Enhanced maintenance via system history and network ring configuration

 

  • Convenient system analyze using Operation history, Error history, System History
  • Ring configuration to prevent a line disconnection error
  • Network monitoring, Protocol monitoring function
  • Error channel monitoring via flag
  • Graphic display for the system configuration
  • Safe module exchange via Wizard



IEC 61131-3 Standard language

  • LD, ST, SFC, IL (read only)
  • Program configuration and data type based on IEC


Variety of communication function

 

  • Easy interface using Open network
  • (Ethernet, Profibus-DP, DeviceNet, RS-232C, RS-422/485, etc)
  • Max.24 communication module installation on the expansion base (High speed link 12, P2P 8)
  • Network diagnosis via network and frame monitoring
  • PLC link via dedicated communication base on Ethernet (RAPIEnet)


Variety of input and output module

  • 8 / 16 / 32 / 64 points (8 / 16 points Relay output)
  • Input / Output / Mixed module


Enhanced analog function

 

  • Enable to install the analog module on the expansion base (Max. 250, Analog input 139)
  • Insulated type and Temperature module
  • Easy to set the parameter via I/O parameter and flag
  • Debugging function via special module monitoring


Integrated programming & engineering environment

  • XG5000 : Easy to program, various monitoring functions and enhanced editing function
  • XG-PD : Convenient setup for communication and network parameter
  • XG-PM software package: Software package for positioning module



Specifications :

 

Item Description Remark
XGR-CPUH/F XGR-CPUH/T
Media Fiber optic Twisted pair  
Operation Method Cyclic execution, Periodic operation,
Interrupt operation, Flxed scan
 
I/O control method Scan synchronized batch
processing method (Refresh method)
 
Program language LD(Ladder Diagram),
ST(Structured Text),
SFC(Sequential Function Chart),
IL(Read only)
 
Number
of
Instructions
Operator 18  
Standard function 130 + Real type function  
Standard function block 41  
Special function/
function block
Special function block, Process
control function block
 
Processing speed LD 0.042 ㎲/Step  
MOV 0.126 ㎲/Step  
Real type ± : 0.602㎲(S), 1.078㎲(D)
X : 1.106㎲(S), 2.394㎲(D)
÷ : 1.134㎲(S), 2.66㎲(D)
S: Real type
D: Long real type
I/O Points 23,808 points
(31 stage *12 slot *64 points)
 
I/O memory I: 131,072 points, Q: 131,072 points
(Total: 1131,072)
 
DRAM Program memory 3MB Including Upload,
Parameter,
Sytem area
*Battery back-up memory: 16MB
Data memory 2MB
System memory 4MB
Flash memory 16MB  
Data
memory
Direct variable 256k Byte  
Auto allocated
variable
512k Byte  
Timer No limitation, Range: 0.001sec ~ 4,259,967.295sec (1,193hours)  
Counter No limitation, Range: -32,768 ~ +32,767  
Flag System 4k Byte  
Comm-
unication
64k Byte L, N area
Special 2k Byte (32base, 16slot, 32channel) U area: Analog
device area
U area: Analog
device area
64k Byte *2) R area: read/write (Command, XG5000)
Program Number of
program blocks
256  
Initial task 1 (_INT)  
Cycle task 32  
Internal
device task
32  
Operation mode RUN, STOP, DEBUG  
Restart mode Warm, Cold  
Self diagnostic functions Watchdog timer, Memory error,
I/O error, Battery error,
Power Supply error
 
Program download RS-232C (1CH), USB (1CH)  
Data retain Auto allocated variable: set by
variable definition
Direct variable: set by parameter
 
Max. expansion base 31 stages  

 

Harga Ladder programming PLC XGR (control panel)

: Rp1

Dapatkan penawaran terbaik untuk
Ladder programming PLC XGR (control panel) !

Nama
Quantity
Unit
Minta Penawaran

Produk Lainnya Dari PT. Taharica

IndoTrading.com adalah media iklan khusus Perusahaan, Toko, Distributor, Grosir, Agen, Supplier, Importir, Exportir, Trading dan Pabrik. Jika Anda tertarik untuk membeli Ladder programming PLC XGR (control panel) ini dengan harga murah, Mohon hubungi Kontak Perusahaan ini diatas.

Jika Anda adalah perusahaan yang ingin menjual di IndoTrading.com , Anda bisa mendaftarkan perusahan Anda disini
Kontak Supplier
Taharica

Verified Supplier
Response Rate :
100%
Jl. Radin Inten II No. 62 Duren Sawit Jakarta Timur, DKI Jakarta - Indonesia

Perusahaan Lainnya yang berkaitan dengan Taharica

PT. Oscar Tunastama

Verified Supplier
Indotrading gold member
1 Tahun
Response Rate 100%

PT JOGJA MITRA PANEL

Verified Supplier
Indotrading gold member
1 Tahun
Response Rate 100%

PD. Hanselindo

Verified Supplier
Indotrading gold member
7 Tahun
Response Rate 100%
Arrow