Spesifikasi RM Young Sensors Relative Humidity & Temperature Probes Models 41382 & 41342

Spesifikasi RM Young Sensors Relative Humidity & Temperature Probes Models 41382 & 41342

Alat Laboratorium Air
RM Young Sensors Relative Humidity & Temperature Probes Models 41382 & 41342

The Model 41382 Relative Humidity/Temperature Probe combines a high accuracy, capacitance type humidity sensor and precision Platinum RTD temperature sensor in one probe. This probe offers a choice of 0-1 VDC or 4-20 mA outputs for T and RH.

Model 41342 Temperature Probe offers accurate temperature-only measurement. Three output options are available: 0-1 VDC, 4-20 mA, and 4 wire RTD. Probes are easily installed in YOUNG naturally ventilated (multi-plate) and aspirated radiation shields. A junction box is provided for cable terminations.

Specifications

 

Power Requirements:

 

Model

 

Input Voltage

      Power

41342

V option

   8-24 VDC

5 mA @ 12 VDC

 

L option

  12-30 VDC

20 mA max

 

 

 

 

41382

V option

   8-30 VDC

7 mA @ 12 VDC

 

L option

   5-30 VDC

46 mA max

 

 

RELATIVE HUMIDITY: (41382)
Measuring Range: 0-100 %RH
Accuracy at 23°C: ±1%RH,
Stability: Better than ±1%RH per year
Response Time: 10 seconds (without filter)
Sensor Type: Rotronic Hygromer™
Output Signal: V option: 0-1 VDC, L option: 4-20 mA


TEMPERATURE: (41382, 41342)
Calibrated Measuring Range: -50 to 50°C (suffix C) -50 to 150°F (suffix F)
Response Time: 10 seconds (without filter)
Accuracy at 23°C: ±0.3°C /optional ±0.1°C NIST calibration - 41342 only
Sensor Type: Platinum RTD
Output Signal: V Option: 0-1 VDC, L Option: 4-20 mA, 4 wire RTD (41342 only)

Recommended Radiation Shields:
Model 41003P Multi-Plate Radiation Shield
Model 43502 Aspirated Radiation Shield


Alat Uji Pengamat Cuaca

Harga RM Young Sensors Relative Humidity & Temperature Probes Models 41382 & 41342

: CALL

Dapatkan penawaran terbaik untuk
RM Young Sensors Relative Humidity & Temperature Probes Models 41382 & 41342 !

Nama
Quantity
Unit
Minta Penawaran

Produk Lainnya Dari PT ANDALAN BANGUN SEJAHTERA

Storage bottle PE HD narrow neck
Alat Laboratorium Umum

Jenco 77
Alat Uji Kualitas Air

Hydrion 9800  pH Strip
Alat Laboratorium Air

Rp 1

IndoTrading.com adalah media iklan khusus Perusahaan, Toko, Distributor, Grosir, Agen, Supplier, Importir, Exportir, Trading dan Pabrik. Jika Anda tertarik untuk membeli RM Young Sensors Relative Humidity & Temperature Probes Models 41382 & 41342 ini dengan harga murah, Mohon hubungi Kontak Perusahaan ini diatas.

Jika Anda adalah perusahaan yang ingin menjual di IndoTrading.com , Anda bisa mendaftarkan perusahan Anda disini
Kontak Supplier / Penjual
ANDALAN BANGUN SEJAHTERA

Verified Supplier
4Tahun Perusahaan ini adalah Anggota Diamond Member Berbayar IndoTrading.com. Kami telah melakukan verifikasi Alamat dan Eksistensi Perusahaan ini.
Response Rate :
66%
Jl. Sumur Batu no. 1 Kemayoran Jakarta Pusat Jakarta Pusat, DKI Jakarta - Indonesia

Perusahaan Lainnya yang berkaitan dengan ANDALAN BANGUN SEJAHTERA

PD. Karya Mitra Usaha

Verified Supplier
Indotrading gold member
1 Tahun
Response Rate 79%

PD. Cipta Bangun Nauli

Verified Supplier
Indotrading gold member
7 Tahun
Response Rate 50%

PD. Karya Mitra Mulia

Verified Supplier
Indotrading gold member
3 Tahun
Response Rate 97%
Arrow