Jual Alat Uji Pretreatmen TCLP - YT30142HW Hazardous Waste Filtration System 142 mm Harga Murah Jakarta oleh PSC
RFQ Logo

Alat Uji Pretreatmen TCLP - YT30142HW Hazardous Waste Filtration System 142 mm

security 100% AMAN BERTRANSAKSI :

Transaksi yang dilakukan di Indotrading dijamin aman karena uang yang Anda bayarkan akan diteruskan kepenjual setelah Indotrading mendapat konfirmasi penerimaaan barang dari kedua pihak. Silahkan melakukan transaksi dengan cara buat permintaan beli, terima penawaran, beli dari penawaran yang Anda terima dan bayarkan biaya ke Indotrading.com Selengkapnya

Spesifikasi Alat Uji Pretreatmen TCLP - YT30142HW Hazardous Waste Filtration System 142 mm

Merck YT30142HW Hazardous Waste Filtration System

USEPA EP Toxicity Test & Toxicity Characteristic Leaching Procedure ( TCLP )

Description

Catalogue Number

YT30142HW

Description

Hazardous Waste Filtration System, 142 mm

Product Information

Connections, Inlet/Outlet

1-1/2 in. Sanitary flange with clamps and adapters for 14 mm ( 9/16 in.) I.D. hose

Connections, Vent/Drain

1/8 in. NPTF

Fitting Inlet

1-1/2 in. Sanitary Flange with clamps and adapters for 14 mm ( 9/16 in.) I.D. hose; 1/8 in. NPTF upstream port for vent/relief

Fitting Outlet

1-1/2 in. Sanitary Flange with clamps and adapters for 14 mm ( 9/16 in.) I.D. hose

Max. Inlet Pressure, bar (psi)

6.9 bar ( 100 psi )

Applications

Application

USEPA EP Toxicity Test & Toxicity Characteristic Leaching Procedure ( TCLP ).

Physicochemical Information

Pressure/Vacuum

Pressure

Dimensions

Height

42.2 cm ( 16.6 in.)

Diameter

18.4 cm

Filtration Area

120 cm²

Weight

12.3 kg ( 27.1 lb.)

Filter Diameter ( ⌀ )

142 mm

Materials Information

Materials of Construction

316 stainless steel; aluminum legs; molded polypropylene handwheels; PTFE seal

Accessories

Description Gasket

Catalogue Number

YY2004057

Description

Gasket, 1-1/2 in., PTFE-coated fluoroelastomer

Packaging Information

Material Size

10

Description Tubing

Catalogue Number

XX6700035

Description

Tubing for pressure use, 1/2 in. ID

Product Information

Max. Inlet Pressure, bar (psi)

9 bar ( 125 psi )

Applications

Application

Accessories for filter holders for sample preparation.

Dimensions

Length

305 cm

Diameter

1.27 cm ( 0.5 in.) ( I.D.)

Materials Information

Chemistry

Polyvinyl Chloride ( PVC )

Packaging Information

Material Size

1

Membrane Filters

Description

Catalogue Number

AP4014250

Description

Glass Fiber Filter without binder

Background Information

Overview

Millipore fibrous disc filters are available in a wide range of flow rates and throughput capacities. Our Glass Fiber filters are available with or without binder resins and can be sterilized by EO, gamma, or autoclave ( 121 °C at 1 bar ).

Glass Fiber Filters with Binder Resin :

Millipore filters with binder resin have superior wet strength and are excellent for qualitative analysis and prefiltration, especially for heavily contaminated liquids. They are also widely used for clarification of aqueous solutions.

Type AP15

Lowest dirt-holding capacity

Recommended prefilter for 0.2 to 0.6 µm filters

Type AP20

Lower retention, higher dirt-holding capacity than AP15 filters

Recommended prefilter for 0.8 to 8.0 µm filters

Use upstream to protect type AP15 filters

Type AP25

Added thickness yields same retention and greater dirt-holding capacity as AP20

Recommended prefilter for 0.9 to 8 µm filters, especially for proteinaceous and heavily contaminated liquids

Use upstream to protect type AP15 filters

Glass Fiber Filters without Binder Resin :

The filters without binder resin retain their structural integrity without weight loss when heated up to 500 °C and can therefore be used in gravimetric analysis as well as for the filtration of hot gases.

Type APFA

Retains fine particles with good efficiency, even at high flow rates

Recommended for monitoring wastewater and collecting suspended particles in gases ( e.g., fumes from chimneys )

Use in biochemical applications ( e.g., collection of cells and filtration of protein or nucleic acid precipitates )

Type APFB

Higher mechanical strength when wet and greater loading capacity than type APFA filters

Use for liquid clarification, quantification of solids in suspensions of fine particles, and scintillation counting

Type APFC

Greater retention, especially for fine particulate and microorganism removal than type APFA filters

Use for determining total suspended solids in drinking water

Use for filtering proteins or nucleic acid TCA precipitates and for collecting cells and microorganisms

Type APFD

Thick filter with high flow and low retention

Use for clarifying suspensions containing particulates greater than 1.0 µm

Type APFF

Use for filtering extremely fine precipitates such as protein, nucleic acids, or serum precipitates

Recommended for USEPA method 1311 for TCLP analysis

Type AP40

Recommended for Standard Methods Total Suspended Solids 2540D

Recommended for USEPA method 1311 for TCLP analysis

Maintains structural integrity without weight loss when ignited to 550 °C ( 1022 °F ) after sample filtration

Recommended for determining volatile suspended matter in wastewater and industrial effluents

Product Information

Filter Code

AP40

Filter Color

White

Maximum Operating Temp.

550 °C

Filter Type

Depth filter

Applications

Application

This is a 142 mm hydrophilic Glass Fiber filter with a 0.7 µm pore size, recommended prefilter for 0.9 to 8 um filters, especially for proteinaceious & heavily contaminated liquids. Can be sterilized by EO, gamma & autoclave.

Biological Information

Wettability

Hydrophilic

Physicochemical Information

Pore Size

0.7 µm

Porosity %

90%

Water Flow Rate

6 mL/min x cm²

Dimensions

Filter Surface

Plain

Thickness

475 µm

Filter Diameter ( ⌀ )

142 mm

Materials Information

Chemistry

Glass Fiber

Packaging Information

Material Size

50 pack, AP40, 142 mm

Description Rotary Agitator

Catalogue Number

YT310RAHW

Description

Millipore Rotary Agitator, 115 V/60 Hz

Physicochemical Information

Voltage

115 V / 60 Hz

Alat Ukur dan Instrumen

Harga Alat Uji Pretreatmen TCLP - YT30142HW Hazardous Waste Filtration System 142 mm

: CALL
Pallscientific, Adalah Perusahaan Swasta Nasional Yang Bergerak Di Bidang Hygiene Industri Dan Kesehatan Lingkungan. Bertujuan Untuk Menjembatani Dan Memenuhi Kebutuhan Dunia Industri Khususnya Dan Masyarakat Pada Umumnya. Perusahaan Yang Bergerak Di Bidang Perdagangan Barang Dan Jasa Dengan Meng-Khususkan Lingkup Usaha Perusahaan Dalam Bidang Pengadaan Peralatan Hygiene Industri Dan Kesehatan Lingkungan, Peralatan Laboratorium, Alat &Ndash; Alat Kesehatan, Serta Penyediaan Jasa Pemantauan, Pengukuran Lingkungan Dan Perbaikan Peralatan.Perdagangan Barang.Produk Yang Diperdagangkan Perusahan Utamanya Adalah Produk Produk Yang Berkaitan Dengan Hygiene Industri, Kesehatan Lingkungan, Kesehatan & Keselamatan Kerja Dan Peralatan Laboratorium Dan Alat Alat Kesehatan . Produk Produk Tersebut Antara Lain :A. Peralatan Pemantau Hygiene Industri Dan Keselamatan Kerja Peralatan Pemantau Higiene Industri Dan Keselamatan Kerja Meliputi :- Alat Ukur Suara ( Sound Level Meter & Noise Dosimeter)- Alat Ukur Getaran ( Vibration Monitoring)- Alat Detector Gas Berbahaya & Mudah Terbakar ( Gas & Flamable GasDetector)- Alat Untuk Pengambilan Sampel Gas, Debu, Mist, Fume & Aerosol ( Gas, Fume,Aerosol Sample Pump & Monitoring)B. Peralatan Pemantau Lingkungan Jenis Peralatan Tersebut Antara Lain :- Peralatan Sampling Dan Analisa Udara Maupun Peralatan Untuk SamplingKualitas Udara Pada Cerobong Secara Isokinetik Otomatis- Alat Pantau Cuaca Stasioner Yang Dilengkapi Dengan Penyimpanan Data ( DataLogging) Sesuai Parameter Yang Diukur.- Peralatan Pemantau Kwalitas Air Bersih Dan Air Minum ( Microbiologi, Ph,Turbiditi Dll..)- Perlatan Pewantau Kadar Kimia Dalam MakananC. Scientific Instrument , Untuk :- Laboratorium Kimia Dasar & Kimia Klinik : Laboratorium Bio Kimia, KimiaKlinik , Kimia Analitik, Mikrobiologi, Hematologi, Parasitologi, KimiaFarmasi & Toksikologi, Serologi, Virologi & Immunologi, Kimia Air, KimiaMakanan & Minuman, Dll- Laboratorium Fisika & Biologi : Laboratorium Instrumentasi, Fisika Dasar,Elektronika Medik, Radiology, Alat Elektronik, Elektronika Medik, Anatomi& Fisiology, Farmakologi Dll.D. Media Dan Reagensia, Untuk: Menunjang Kebutuhan Reagent Pada Rumah Sakit ,Puskesmas, Klinik, Dan Laboratorium.

Kami Menjual
  • Environmental
  • Medical
  • Instruments
  • Agriculture
  • Laboratory
  • Safety Equipment

Dapatkan penawaran terbaik untuk
Alat Uji Pretreatmen TCLP - YT30142HW Hazardous Waste Filtration System 142 mm !

Nama
Quantity
Unit
Buat Permintaan

Simulasi Pinjaman Usaha

Rp (Juta)
%
Hari
Hari
Hari
Rp (Juta)

PERUSAHAAN TERKAIT

Abadilab Instrument

Verified Icon Verified
Indotrading gold member
2 Tahun
Response Rate 20%

CV. Kharisma Mandiri

Verified Icon Verified
Indotrading gold member
3 Tahun
Response Rate 25%

PT YAKIN MAJU SENTOSA

Verified Icon Verified
Indotrading gold member
3 Tahun
Response Rate 26%
IndoTrading.com adalah media iklan khusus Perusahaan, Toko, Distributor, Grosir, Agen, Supplier, Importir, Exportir, Trading dan Pabrik. Jika Anda tertarik untuk membeli Alat Uji Pretreatmen TCLP - YT30142HW Hazardous Waste Filtration System 142 mm ini dengan harga murah, Mohon hubungi Kontak Perusahaan ini diatas.

Jika Anda adalah perusahaan yang ingin menjual di IndoTrading.com ,
Perusahaan
PSC

1 Tahun Perusahaan ini adalah Anggota Platinum Member Berbayar IndoTrading.com. Kami telah melakukan verifikasi Alamat dan Eksistensi Perusahaan ini.
Response Rate :
reply_all 98%
Lindeteves Trade Center LTC Lantai 1 Blok B 21 No.3 Jl. Hayam Wuruk 127 Glodok Jakarta Barat 11180 Jakarta Barat, DKI Jakarta - Indonesia
Arrow