Lihat Detail
1 / 3
AEMC Digital Transformer Turns Ratiometer Model 8511 aemc
Harga tidak mengikat dan sewaktu-waktu dapat berubah. Dapatkan harga terbaik dengan klik tombol Minta Penawaran
- Stok
- 0
- Negara Asal
- Australia
- Dikirim Dari
- Bekasi Utara, Bekasi
- Kategori
- Alat Laboratorium Umum
- Update Terakhir
- 22 Okt 2026
Spesifikasi AEMC Digital Transformer Turns Ratiometer Model 8511 aemc
Cari berbagai macam dari pilihan terlengkap Alat Laboratorium Umum.
AEMC Digital Transformer Turns Ratiometer Model 8511 aemc
SPESIFIKASI DIGITAL TRANSFORMER TURNS RATIOMETER MODEL 8511
Merek/Model: AEMC Instruments DTR 8511
Jenis: Alat ukur rasio lilitan transformator digital
Aplikasi: Transformator daya, VT/PT, dan CT
Rentang rasio VT/PT: 0,8000:1 hingga 8000:1
Rentang rasio CT: 0,8000:1 hingga 1000:1
Akurasi VT/PT: ±0,1% hingga ±0,25%, tergantung rentang ukur
Akurasi CT: ±0,5% dari pembacaan
Arus eksitasi: Hingga 2 A
Tegangan pengujian: 30 V untuk VT/PT dan 2 V untuk CT pada 64 Hz
Fungsi: Pengukuran rasio, polaritas, arus eksitasi, kontinuitas lilitan, dan deviasi rasio
Penyimpanan data: Hingga 9.801 hasil pengukuran
Komunikasi: USB Type-A/Type-C
Perangkat lunak: DataView
Catu daya: Baterai isi ulang NiMH dan adaptor
Layar: LCD, 4 baris
Berat: Sekitar 3,2 kg
Catatan:
Alat digunakan untuk menguji rasio transformator dalam kondisi tidak bertegangan.
Akurasi bergantung pada rentang pengukuran dan kondisi pengujian.
AEMC Digital Transformer Turns Ratiometer Model 8511 aemc
DIGITAL TRANSFORMER TURNS RATIOMETER MODEL 8511 SPECIFICATIONS
Brand/Model: AEMC Instruments DTR 8511
Type: Digital Transformer Turns Ratiometer
Applicatons: Power transformers, VT/PTs, and CTs
VT/PT ratio range: 0.8000:1 to 8000:1
CT ratio range: 0.8000:1 to 1000:1
VT/PT accuracy: ±0.1% to ±0.25%, depending on measurement range
CT accuracy: ±0.5% of reading
Excitation current: Up to 2 A
Test voltage: 30 V for VT/PT and 2 V for CT at 64 Hz
Functions Ratio, polarity, excitation current, winding continuity, and ratio deviation measurement
Data storage: Up to 9,801 measurements
Communication: USB Type-A/Type-C
Software: DataView
Power supply: Rechargeable NiMH batteries and adapter
Display: 4-line LCD
Weight: Approximately 3.2 kg
Note:
The instrument is intended for testing de-energized transformers.
Accuracy depends on the measurement range and test conditions.
Referensi resmi / Official reference: AEMC Instruments – DTR Model 8511
Tidak menemukan produk yang Anda cari ?Minta penawaran sekarang
Detail Perusahaan
- Tahun Berdiri
- 2000
- Bidang Perusahaan
- -
- Jumlah Karyawan
- -
- Kami Menjual
- Alat Laboratorium,Rotary Evaporator,Earth Tester,Digital Multimeter,Termometer Digital,Pompa Vakum
- Alamat
- Jl. Jupiter VI, Perum Bintang Metropol Blok A7 No.16 Bekasi Utara 17122
Perwira, Bekasi Utara, Bekasi, Jawa Barat